Horizontal hand brush filter performance table
Specification |
In&out Diameter |
Nets tube diamete |
Ø |
L |
L1 |
L2 |
L3 |
H |
Max Flow |
weight |
mm |
in |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
(T/h) |
(kg) |
YL-2S |
50 |
2 |
57 |
159 |
300 |
600 |
80 |
810 |
650 |
19 |
70 |
YL-3S |
80 |
3 |
89 |
159 |
300 |
600 |
80 |
810 |
660 |
50 |
75 |
YL-4S |
100 |
4 |
108 |
159 |
300 |
700 |
80 |
810 |
670 |
80 |
80 |
YL-5S |
125 |
5 |
133 |
219 |
350 |
750 |
80 |
820 |
680 |
125 |
90 |
YL-6S |
150 |
6 |
159 |
275 |
350 |
800 |
80 |
950 |
720 |
180 |
100 |
YL-8S |
200 |
8 |
219 |
325 |
525 |
850 |
80 |
1050 |
850 |
320 |
120 |
YL-10S |
250 |
10 |
273 |
377 |
650 |
900 |
80 |
1350 |
1050 |
490 |
150 |
YL-12S |
300 |
12 |
325 |
426 |
700 |
950 |
100 |
1740 |
1360 |
710 |
260 |
YL-14S |
350 |
14 |
377 |
478 |
820 |
1170 |
100 |
2350 |
1740 |
970 |
350 |
Vertical hand brush type filter
Part number |
In&out parameter |
Drainage outlet parameters |
H |
S1 |
S2 |
Flow(T/h) |
Weight(Kg) |
|
in |
D1 |
D2 |
D3 |
YL-2Y |
50 |
2 |
Φ150 |
Φ240 |
Φ285 |
517 |
300 |
225 |
19 |
80 |
YL-2.5Y |
65 |
|
Φ150 |
Φ240 |
Φ285 |
517 |
300 |
225 |
28 |
100 |
YL-3Y |
80 |
|
Φ150 |
Φ240 |
Φ285 |
537 |
300 |
225 |
50 |
130 |
YL-4Y |
100 |
|
Φ207 |
Φ295 |
Φ340 |
587 |
300 |
225 |
80 |
150 |
YL-5Y |
125 |
|
Φ260 |
Φ350 |
Φ395 |
630 |
300 |
285 |
125 |
180 |
YL-6Y |
150 |
|
Φ309 |
Φ400 |
Φ445 |
641 |
300 |
311 |
180 |
230 |
YL-8Y |
200 |
|
Φ367 |
Φ460 |
Φ505 |
823 |
398 |
340 |
320 |
280 |
YL-10Y |
250 |
|
Φ406 |
Φ515 |
Φ565 |
975 |
423 |
365 |
490 |
320 |
YL-12Y |
300 |
|
Φ406 |
Φ515 |
Φ565 |
1000 |
438 |
365 |
710 |
380 |
YL-14Y |
350 |
|
Φ460 |
Φ565 |
Φ615 |
1068 |
463 |
395 |
970 |
450 |
F type Table
Part number |
A |
B |
C |
D |
E |
YLSF2 |
460 |
1190 |
1750 |
465 |
228 |
YLSF4 |
460 |
1210 |
1770 |
465 |
228 |
YLSF6 |
620 |
1740 |
2800 |
470 |
235 |
YLSF8 |
800 |
1840 |
2900 |
545 |
308 |
Technical parameter
※Working pressure: ≤ 1.0MPa (more than this pressure, Please specify when ordering)
※Loss of pressure:≤0.015MPa
※Working Temperature:≤150℃
※Filter precision:d=1.2mm
Other: filtering accuracy and size according to user requirements Custom-made flange connection dimensions according to GB-9119.8-88.
Method of type selection
(1) To determine the following parameters: maximum flow or diameter of the import and export the DN, the maximum working pressure P, the operating temperature, filtering accuracy.
(2) Determine the structure according to the site installation location.
(3) to determine the materials: the filter material, the shell material.
(4)Determine the filter model.
Installation and use
Hand brush filter can be installed horizontally or vertically, b, ut should pay attention to the flow direction of the shell direct, ion of the arrow should be perpendicular to the requirements of the direction of flow is from top to bottom. When the import and export pressure differential pressure of 0.04MPa, the need to open the drain valve, manual turning the handle gently scrub the filter until the outfall effluent water to clear, stop brushing and sewage, the sewage process system normal operation, with no downtime.
Standard filter level