Function and Scope of application
At right angles to the filter for multi-functional system components and filtering capabilities. The filter self-cleaning ability, do not always cleaning the filter. Effective exclusion of the oxide scale, the old dirt, sludge and air and other impurities in the water system to give full play to ensure the water quality clean. The product is widely used in industrial cooling water system, air conditioning water systems, heat exchange water systems, the production of domestic hot water supply systems, hot water heating boiler water system.
Main technical parameter
(1)Scope of pressure:0.6、1.0、1.6MPa;
(2)Max operating temperature:95℃;
(3)Specification:DN80-DN600;
(4)Scope of flow:15-2800m3/h;
(5)Filters commonly used specifications: 8,10,14,20,30,70,150 mesh / inch
(6)blow down rate:99%;
(7)Special specifications according to users' requirements.
Specification |
Reference flow(T/h) |
A |
D |
B |
H |
50 |
5-7 |
340 |
159 |
150 |
25 |
65 |
8-11 |
390 |
159 |
150 |
25 |
80 |
15-20 |
440 |
219 |
180 |
25 |
100 |
25-35 |
490 |
273 |
210 |
25 |
125 |
45-60 |
560 |
325 |
240 |
40 |
150 |
60-85 |
640 |
377 |
260 |
40 |
200 |
90-130 |
730 |
426 |
300 |
40 |
250 |
150-260 |
820 |
470 |
320 |
50 |
300 |
250-400 |
930 |
500 |
340 |
50 |
350 |
450-650 |
1060 |
600 |
390 |
50 |
400 |
650-900 |
1200 |
700 |
450 |
65 |
450 |
900-1100 |
1310 |
800 |
500 |
65 |
500 |
1150-1500 |
1420 |
900 |
560 |
65 |
550 |
1300-1700 |
1510 |
900 |
570 |
80 |
600 |
1600-2000 |
1570 |
1000 |
650 |
80 |
650 |
1900-2300 |
1660 |
1000 |
650 |
80 |
700 |
2200-2700 |
1710 |
1100 |
700 |
80 |
Product feature
1, Vertical, horizontal arbitrarily small space area;
2, The import and export angle 0 °, 90 °, 180 °, 270 °. Any angle, flexible room layout;
3, Self-cleaning filter functions without opening the lid to clean the filter;
4, To reduce system corrosion protection of the water pump impeller;
5, The capacity to accommodate dirt;
6, The resistance is small parts;
7, The dirt to increase the resistance of the system unchanged;
8, The form, T-,. We have the right angle type, type Ⅰ and type Ⅱ various forms of center magnetic field strength :4000-5000 Gauss.
Install matter
1) The installation should pay attention to the direction of the arrow on the shell (horizontal or down consistent with the direction of flow of the medium);
2) It is best to set the bypass pipeline, in order to filter for cleaning or failure does not affect the normal operation;
3) Filter the water processor equipment for use, should be installed before the water treatment equipment inlet.