Vertical P Type Backwash Sewage Water Filter

Part number

A
(mm)


(mm)

weight
(Kg)

In&Out size

D
(mm)

Max Flow
(T/h)

mm

in

YL-2P

410

159

13

50

2

25

19

YL-2.5P

410

159

15

65

2.5

25

28

YL-3P

500

219

18

80

3

25

50

YL-4P

580

219

25

100

4

40

80

YL-5P

640

219

39

125

5

40

125

YL-6P

730

273

55

150

6

50

180

YL-8P

900

325

85

200

8

50

320

YL-10P

1050

377

120

250

10

50

490

YL-12P

1300

426

150

300

12

65

710

YL-14P

1450

478

220

350

14

65

970

YL-16P

1600

530

280

400

16

65

1260

YL-18P

1800

630

350

450

18

100

1590

YL-20P

2000

720

420

500

20

100

1970

YL-24P

2200

800

580

600

24

100

2850

 

               P type recoil sewage filter                             Vertical P type recoil sewage filter

Structure&Working Principle

  P-type recoil sewage filter quality carbon steel tube, the special structure of the stainless steel wedge filter, valve and sewage equipment. When the filters work, the butterfly valve is turned on, the water flow from the inlet into the filter, filter-filter to export. When the filter needs to sewage, close the butterfly valve, open the drain valve, the water filtered by the filter before the second half of the part of the water inflow by the export system, the remaining water from the filter after the first half of the outside into the inside, by the outfall discharge from the automatic flushing to reverse the role of the filter. The entire process of flushing the system can work properly, with no downtime.

Technical Parameter

1、Treatment effect
※Filtering accuracy: according to user needs
※Filtering efficiency:80%~99%
※Pressure loss:≤0.015Mpa
2、Water quality
※Working pressure:≤1.6Mpa
※Working temperature:0℃~120℃
※Working environment&temperature:-25℃~+50℃
※Relative humidity:﹤95%
3、Operating parameter
※MTBF:﹥60000h
※Degigned life:20years
Other: work pressure, filtration precision and
specification size according to user require special manufacturing, flange connection dimensions according to GB-9119.8-88
P-type recoil sewage filter should be installed horizontally or vertically when mounted vertically, the flow direction is from top to bottom, the installation should pay attention to the direction of the arrow on the housing must be consistent with the flow, normal operation, the butterfly valve is turnedwhen the need of sewage, close the butterfly valve, open the drain valve until the discharge water quality clear so far. Close the drain valve, open the butterfly valve to complete the process of sewage, and equipment in normal operation.