Innder magnetic water processor
  The magnetic water treatment device using magnetic fields to be processed on the water, do not change the chemical composition of the water under the premise of changing the physical structure of water, so as to achieve scaling, cleaning, sterilization, algae, anti-corrosion, anti-rust water purposes. This is an advanced physical water treatment, the effect is good, low cost, no maintenance, no pollution. The product is widely used in industry, construction, chemical, electric power, metallurgy, rubber, textile, food, cooling water circulation system, air conditioning and refrigeration systems, heat exchange systems and hot water boiler systems.
  Advantage of the tremendous energy of the neodymium iron boron rare earth permanent magnet materials, optimized design, formation of the vertical center of the multi-peak magnetic field. Water or fluid to ≥ 51.5 m / sec speed through the vertical magnetic field, electromotive force, so that the lattice refinement in raw water, dirt crystal particle size from about 3.39 microns, about 0.22 microns into , and the faster the flow rate, the greater the electromotive force generated, the treatment effect is more ideal, so as to achieve the purpose of scaling, cleaning.

Sterilization alga principle
  NdFeB magnetic field of the magnetic water treatment device on the waves generated turbulence, destruction of cell membrane ion channels, change the cell to adapt to the internal control current and the environmental conditions necessary for survival, and loss of viability and death. At the same time, water molecules can be magnetically actuated water dissolved oxygen surrounded by blockade and destruction of microbial life-reaction required oxygen source, so as to achieve a good sterilization algicide effect to prevent the production of biological sludge.

Resistance rust corrosion principle
  Metal corrosion requires oxygen, the role of high frequency electromagnetic energy package of a single water molecule dissolved oxygen molecules dissolved in water, so that the dissolved oxygen in the inert oxygen, sealing off the source of oxygen required for metal corrosion. The same time, high-frequency electromagnetic waves stirred up the overhanging composite modulation frequency of the electromagnetic field generated by the "skin effect", gathered in excess of negative charge in the wall, gathered in the inside water of excess positive charge.Positive charge is a strong rejection of the same sex of Fe3 positively charged, to prevent Fe of Fe3 lose electrons to become separated from the metal wall into the water; excess negative electrons on the wall continue to attract the positively charged Fe3 hinder Fe3 dissolved in water; so that the original wall on the Fe2O3 (red rust) to restore the outer membrane of Fe3O4 strong corrosion resistance force black rust. 

The effects of water processor

Scope of Application
A variety of the growth of bacteria, algae and easy raw scale water system.
ΔAir conditioning, cooling water circulation system.
ΔA variety of heat exchanger and cooling tower systems.
ΔThe pool system.

 water pipe magnetic processor
Technical feacture:
ΔHigh-tech: the United States Aeronautics and Space Administration (NASA) research success and I applied in China to deepen research and was a major breakthrough, a high-tech products is recommended by the National Science and Technology Commission and the Ministry of Construction.
ΔHigh efficiency: thermal efficiency can be increased more than 20% of the equipment, continuous operation without cleaning.
ΔSecurity: low operating voltage.
ΔEnvironmental protection: no chemicals, no secondary pollution.
ΔEnergy, water and long life, continuous operation for more than 15 years. Small size, easy to install, no management.
ΔInvestment is small, fast recovery, and 1 to 2 years to recover the full costs of the central air conditioning system. Industrial water system within six months to recover all costs.
Processor specification model and operating parameters of the magnetic water
Part number
In&out Caliber
overall dimension
flow
vertical centre
medium working
weight
mm
in
OD×L
m3/h
stong magnetic(mt)
temperature(℃)
kg
YLC-1
25
1
108×330
4.9
160
0-90
10
YLC-1.5
40
1.5
108×330
12
160
0-90
20
YLC-2
50
2
159×450
19
160
0-90
30
YLC-2.5
65
2.5
159×450
28
160
0-90
40
YLC-3
80
3
159×450
50
160
0-90
45
YLC-4
100
4
219×560
80
160
0-90
50
YLC-5
125
5
219×600
125
160
0-90
60
YLC-6
150
6
273×740
180
160
0-90
70
YLC-8
200
8
325×790
320
160
0-90
90
YLC-10
250
10
377×850
480
160
0-90
110
YLC-12
300
12
426×900
600
160
0-90
130
YLC-14
350
14
478×950
750
160
0-90
160
YLC-16
400
16
530×1000
850
160
0-90
210
YLC-18
450
18
620×1050
950
160
0-90
260
YLC-20
500
20
720×1100
1100
160
0-90
260