Chlorine dioxide generator

 Product Instruction

  YL series of efficient mixing disinfectant generator plant digestion and absorption of advanced U.S. technology, combined with China's national conditions and specific characteristics, on the basis of the original disinfectant generator, electrode material, the positive cathode spacing, the electrolysis area of ​​diaphragm materials and has done repeated tests, well-designed. Mainly generated by the electrolysis occurred CIO2 mixed with CI2, O3, H2O3, and other strong oxidants, has a broad spectrum of oxidation and sterilization, can kill a variety of Bacillus virus in water. By the Beijing Municipal Health and Epidemic Prevention Station of five series thirteen disinfectants on the market effect of the test, proved CIO2 best, the average kill rate of 100% within five minutes. While oxidation of organic compounds in water and phenol, Fe2 + of Mn2 +, CN-material, and does not produce chloroform (carcinogen), chlorophenols, and so on. By the Chinese Academy of Preventive Medicine tests proved bactericidal capacity than at present all kinds of disinfectants, especially in the toxicity of safe and reliable drinking water disinfection. Therefore, a wide range of use value, reached the nineties international advanced level.

1, A variety of disinfection of the water plant.
Two high-rise buildings of secondary water supply, drinking water disinfection.
3, the drinking water of the vast rural areas, towns, mines, military units and field staff, railway disinfection of the water stations.
4, Swimming pool, Jacuzzi, water are sterilized.
5, power plants, boilers and other industrial algae removal of cooling circulating water sterilization.
6, The water in the sterilization and in addition to smell.
7, A variety of wastewater treatment disinfection.
8, Restaurants, hotels, tableware are sterilized.
9, The food and beverage plants, containers are sterilized.
10, Dairy plant, slaughtering plant pipeline environment are sterilized, disinfected.
11, Hospital sewage, and equipment are sterilized.
12, Broken cyanide plating wastewater containing cyanide.
13, Printing and dyeing wastewater are from phenol.
14, The phenol removal by treatment of phenolic wastewater.
15, Oil pipelines, sulfate-reducing bacteria elimination is.
Different pH values ​mixed disinfectant chlorine dioxide the average killing rate of bacterial spores
2.13
250
100.00
125
100.00
11.80
50
99.000
250
94.93
250
2-13
100.00
250
6-7
99.60
250
6-7
97.00
Consumers wash disinfectant
250
11-12
95.90
250
11-12
84.60
250
-
99.80
250
-
98.90
Hydrochloric acid compound disinfectant
Liquid-type concentration
3.0
99.80
Chlorhexidine too compound disinfectant
Liquid-type concentration
6.58
72.05
250
6-7
40.42
Equipment constitute
A certain concentration or saturated salt solution in the electrolytic cell the anode chamber, while the water to join the electrolyzer cathode chamber, connected to the 12V DC power supply to start electrolysis to generate CIO2, CL2, H2O2, and mixed disinfectant, ejector vacuum tubeRoad gas inhalation in the water disinfection.
 
Equipment feature
1, strong integrity, small size, light weight, beautiful appearance.
2, The anode life of is up to 5-7 years.
3, Power performance is reliable, the use of SCR DC power supply.
4. Corrosion, electrolytic cell for high-quality titanium and PVC.
5, The diaphragm conductivity, easy to replace.
6, Close the valve UPVC engineering plastics.
A variety of environments dosage reference table
Table3
Environment
Application quantity
drinking water
high-rise buildings
twice water supply
Swimming pool water
shower water
bath water
Hospital sewage
Cyanide waste water
G气/m2.水
0.1-1.2
0.1-0.5
2-5
0.5-2.0
10-30
20-40
30-45
Other sewage, as the raw water composition the accountants are prior testing to determine.
 Installation requests
1. selection of equipment should be indicated directly or indirectly dosing. The indirect method simply connect the DN2, the DN3, the direct method the DN1, DN2, the DN3 need to be connected.
2、The equipment is arranged in the concrete on the basis of size (A +200) × (B, +200) × 100mm. Electrical cabinet and generator body can be unified to establish a foundation, electrical cabinet and the equipment is appropriate spacing to 300mm.
3、Room feudal design should consider sewage leakage and ventilation outlet. In addition, in the selection of the factory can provide the suction hood and fan specifications and export orientation.
4.The factory of the product to provide the equipment foundation drawings, took over the diagram.